Highlights of Update - V2.6.0
- Enhanced multi-protocol communication architecture improves internal system coordination, enabling smoother coexistence of OPC DA with industrial communication protocols such as BACnet, Modbus, OPC UA, MQTT, and others within a unified automation platform.
- Optimized configuration and monitoring workflows provide a more intuitive system setup experience, improving navigation, simplifying device configuration, and enabling faster system deployment and monitoring.
- Improved background data acquisition stability enhances communication reliability for S7 and Omron PLC devices, ensuring consistent data collection and reducing the risk of interruptions in industrial data processing.
- Enhanced runtime and designer data handling ensures more reliable real-time data updates, improving the stability and synchronization of live data delivered from data services to visualization and application layers.
New Features
End-to-End OPC DA Platform Support
Version 2.6.0 introduces complete OPC DA support across the entire platform, enabling seamless connectivity with OPC DA servers used in industrial automation systems. This integration allows the platform to communicate with legacy and modern systems while maintaining compatibility with existing industrial protocols.
OPC DA Data Service
Historical data logging for OPC DA tags allows users to store and analyze past operational data for trend monitoring, analysis, and performance reporting. The system can also generate alarms based on OPC DA values, helping operators quickly detect abnormal conditions and respond faster to critical events. Additionally, users can view live device connection status and real-time OPC DA tag values directly in the configurator for better visibility and monitoring.
OPC DA Event Support in Designer Workflows
Designer now supports OPC DA-based events across multiple workflow components, including Query Designer, Set Value functions, and the Condition Editor. This allows developers to build automation logic and UI interactions directly based on OPC DA data changes.
Subscription and Polling Data Collection
The platform supports both Subscription (Change of Value) and Polling mechanisms for OPC DA data collection. This allows users to choose the most efficient method depending on the device capabilities and application requirements.
Improvements
Enhanced Multi-Protocol Communication Architecture
The internal communication architecture has been improved to ensure smoother integration and coexistence of multiple industrial protocols within a single platform. Protocols such as OPC DA, BACnet, Modbus, OPC UA, MQTT, and others can now operate more efficiently together, providing better interoperability and stable data exchange across different industrial systems.
Streamlined Configuration and Monitoring Workflow
Configuration and monitoring workflows have been optimized to provide faster setup, clearer navigation, and a more intuitive user experience. These improvements help users configure systems more efficiently and monitor devices with greater ease.
Improved Stability for PLC Data Acquisition
The stability of background data acquisition processes has been improved, particularly for S7 and Omron PLC communication. This enhancement ensures more reliable data collection and minimizes interruptions in industrial data processing.
Enhanced Reliability of Live Data Updates
The system now provides more reliable handling of continuous live data updates that are delivered to Runtime and Designer modules. This improvement ensures smoother real-time monitoring and better synchronization between data services and visualization components.
Release Notes
Stay up to date with the latest features, improvements, and fixes in AdiLogiX
Platform-wide - V2.6.0
🟢New Features
- Introduced full end-to-end OPC DA support across the platform, enabling seamless connectivity with OPC DA Servers in Industry 4.0 control systems.
- The platform now supports real-time reading, writing, historical data logging, and alarm generation for OPC DA sources — ensuring complete bidirectional communication and consistent data management alongside existing protocols.
🟡Improvements
- Improved internal communication architecture to ensure smoother coexistence of OPC DA, BACnet, Modbus, OPC UA, MQTT, and other supported protocols within a single unified platform.
- Streamlined configuration and monitoring workflows for faster setup, clearer navigation, and more intuitive system operation.
Configurator - V2.6.0
🟢New Features
- Introduced a dedicated OPC DA Configuration module to add, manage, and organize OPC DA servers and their associated tags with ease.
- Added network-based discovery of OPC DA servers, enabling fast and effortless device onboarding.
- Implemented automatic discovery of OPC DA Items from connected devices, allowing rapid and accurate tag configuration.
- View real-time device connection status along with live tag values directly within the configurator.
- Supports both Subscription (COV) and Polling mechanisms for efficient and reliable data collection.
- Extended History and Alarm setup to include OPC DA tags, providing consistent historical logging and alarm management across BACnet IP, Modbus, OPC UA, S7, MQTT.
Designer - V2.6.0
🟢New Features
- Added comprehensive OPC DA support across Designer workflows, enabling OPC DA based events in all controls, including:
- Query Designer
- Set Value function calls
- Condition Editor
🔵Fixes
- Miscellaneous minor bug fixes and stability improvements.
- Fixed issues impacting layout and component rendering across different DPI/scaling settings.
Data service - V2.6.0
🟢New Features
- Introduced full OPC DA communication capabilities, including device connection management, disconnection handling, and scheduled data acquisition tasks.
- Enabled real-time delivery of OPC DA data to runtime applications, along with integrated alarm generation and historical data logging based on OPC DA inputs.
🟡Improvements
- Improved stability of background data acquisition processes for both S7 and Omron PLCs.
- Enhanced reliability in handling continuous live data updates sent to Runtime and Designer.
Runtime - V2.6.0
🟢New Features
- Added support for live visualization of OPC DA data in trending charts, enabling continuous monitoring of integrated data sources.
🔵Fixes
- Fixed a minor issue in the trending chart feature.
- Resolved small layout inconsistencies in certain dashboard components.